| Acoustical (each loudspeaker) |
Operating Frequency Range ( 1)
|
...
|
±4 dB from 50 Hz to 18 kHz
|
|
|
... |
±90° from 200 Hz to 16 kHz
|
|
|
... |
139 dB peak @ 1 meter
|
|
Dynamic Range
|
... |
> 110 dB
|
|
| Coverage |
| |
... |
50° Horizontal x 50° vertical |
|
| Transducers |
|
Low Frequency
|
...
|
12" Cone driver
|
|
High Frequency
|
...
|
2" Throat, 4" diaphragm compression driver
|
|
| Audio Input |
|
Type
|
...
|
10 k ohm impedance, electronically balanced
|
|
Connector
|
... |
Female XLR input and male XLR output or VEAM
|
|
Nominal Input Level
|
... |
+4 dBu (1.23 Vrms)
|
|
| Amplifiers |
|
Type
|
...
|
Complementary power MOSFET output stages (audio class AB/H)
|
|
|
... |
1240 Watts (620 watts/channel)
|
|
THD, IM, TIM
|
... |
< .02 %
|
|
| AC Power |
|
Connector
|
...
|
250 V NEMA L6-20 (Twistlock) inlet or IEC 309 male inlet
(3)
|
|
Automatic Voltage Selection
|
... |
85 - 134 VAC; 165 - 264 VAC; 50/60 Hz (4)
|
|
Operational Voltage Range
|
... |
Turn on: 85 VAC; Turn off: 134 VAC; 50/60 Hz
|
|
|
... |
Turn on: 165 VAC; Turn off: 264 VAC; 50/60 Hz
|
|
Max.Continuous RMS Current (> 10 sec)
|
... |
at 115 V: 8 A rms
at 230 V: 4 A rms
at 100 V: 10 A rms
|
|
Burst RMS Current (< 1 sec)
|
... |
at 115 V: 15 A rms
at 230 V: 8 A rms
at 100 V: 18 A rms
|
|
Max Peak Current During Burst
|
... |
at 115 V: 22 A pk
at 230 V: 11 A pk
at 100 V: 25 A pk
|
|
Inrush current
|
... |
< 12 A at 115 V
|
|
| Physical |
|
Dimensions
|
... |
24.00" w x 18.00" h x 14.69" d
(610 mm x 457 mm x 373 mm)
|
|
Weight
|
... |
90 lbs (40.82 kg); Shipping: 105 lbs (47.63
kg)
|
|
Enclosure
|
... |
All birch plywood
|
|
Finish
|
... |
Black textured
|
|
Protective Grille
|
... |
Perforated steel grille, charcoal-grey foam
|
|
| Notes |
|
1. Subject to half-space loading, measured with one-third octave
frequency resolution in fixed ISO bands.
2. Nominal 8 ohm resistive load, pink noise, 100 V peak.
3. Other connectors available. Fore European applications, the
IEC 309 (16 A) panel is used.
4. The unit is rated at 88-125 V and 182-235 V, 50/60 Hz, to satisfy
EC standards for -10% to 6% AC line voltage.
|